Interlogix GE-DSH-73 Series User Manual User Manual
Page 65

Chapter 5: Web-Based Management
GE-DSH-73/DSH-82 and DSH-82-PoE User Manual
61
UTC Timezone:
Universal Time, Coordinated. Set the switch location time zone. The 
following table lists the different location time zone for your reference. 
SNTP Sever URL:
Set the SNTP server IP address. You can assign a local network time 
server IP address or an internet time server IP address. 
Switch Timer:
When the switch has successfully connected to the SNTP server whose 
IP address was assigned in the column field of SNTP Server URL, the 
current coordinated time is displayed here. 
Daylight Saving Period:
Set up the Daylight Saving beginning date/time and Daylight Saving 
ending date/time. Please key in the value in the format of ‘YYYYMMDD’ 
and ‘HH:MM’ (leave a space between ‘YYYYMMDD’ and ‘HH:MM’). 
YYYYMMDD: an eight-digit year/month/day specification.
HH:MM: a five-digit (including a colon mark) hour/minute specification.
For example, key in ‘20070701 02:00’ and ‘20071104 02:04’ in the two 
column fields respectively to represent that DST begins at 2:00 a.m. on 
March 11, 2007 and ends at 2:00 a.m. on November 4, 2007. 
Daylight Saving Offset 
(mins): 
For non-US and European countries, specify the amount of time for 
day light savings. Please key in the valid figure in the range of minute 
between 0 and 720, which means you can set the offset up to 12 
hours. 