Digital Input/Output (GE-DSH-73)
The 7 10/100TX + 3 10/100/1000T/100/1000 SFP Combo w/ X-Ring L2 Managed
Industrial Switch contains two digital inputs and two digital outputs. The digital inputs
may be used to receive the voltage-changing signal of the remote equipment to
sense the state of the remote equipment like heater, pump, and other electrical
equipment. Therefore the switch can be configured to send system log, SMTP and
SNMP traps to syslog server, SMTP server and SNMP trap station respectively (please
refer to System Event Log and SNMP configuration section). Outputs are open-
collector transistor switches used to connect to the external device like alarm buzzer
or LED to inform the user of the port/power status.
Digital Input
• When First/Second Digital Input function is enabled, First Digital Input/Second
Digital Input will then be available respectively.
• Digital Input: Choose the transition type to trigger DI0/DI1.
o
Low-->High: Having focused this radio button, DI0/DI1 will only report the
status when the external device's voltage changes from low to high.
o
High-->Low: Having focused this radio button, DI0/DI1 will only report the
status when the external device's voltage changes from high to low.
• Event description: Please fill in the description for the event.
• Action: Tick the check boxes to decide whether or not to send the events via
Syslog, SMTP, or SNMP Trap.
Figure 5-72: Digital Input interface
Digital Output
• When First/Second Digital Output function is enabled, First Digital Output/Second
Digital Output will then be available respectively.