beautypg.com

Interlogix GE-DSH-73 Series User Manual User Manual

Page 138

background image

Chapter 5: Web-Based Management

134

GE-DSH-73/DSH-82 and DSH-82-PoE User Manual

Object

Description

Determined Class

Displays the PD’s class.

Class 0 is the default for PDs. However, to improve power management
at the PSE, the PD may opt to provide a signature for Class 1 to 3.

The PD is classified based on power. The classification of the PD is the
maximum power that the PD will draw across all input voltages and
operational modes. A PD shall return Class 0 to 3 in accordance with the
maximum power draw as specified by Table 5-12-1.


And then, click APPLY to carry into effect.

PD Classifications
A PD may be classified by the PSE based on the classification information provided by
the PD. The intent of PD classification is to provide information about the maximum
power required by the PD during operation. Class 0 is the default for PDs. However, to
improve power management at the PSE, the PD may opt to provide a signature for
Class 1 to 3.
The PD is classified based on power. The classification of the PD is the maximum
power that the PD will draw across all input voltages and operational modes.
A PD shall return Class 0 to 3 in accordance with the maximum power draw as
specified by Table 5-3.

Table 5-3: Device class

Class Usage

Range of maximum power used by the PD

0

Default

0.44 to 12.95 Watts

1

Optional

0.44 to 3.84 Watts

2

Optional

3.84 to 6.49 Watts

3

Optional

6.49 to 12.95 Watts

4

Not Allowed Reserved for Future Use

Class 4 is defined but is reserved for future use. A Class 4 signature cannot be
provided by a compliant PD.

This manual is related to the following products: