Chapter 4: Console Management

38

GE-DSH-73/DSH-82 and DSH-82-PoE User Manual

Login in the Console Interface

To configure the system, connect a serial cable to a COM port on a PC or notebook
computer and to RJ-45 type serial (console) port of the Managed Industrial Switch.
The console port of the Managed Industrial Switch is DCE already, so that you can
connect the console port directly through PC without the need of Null Modem.

Figure 4-2: Connecting the Switch to a PC

A terminal program is required to make the software connection to the GE-DSH series
Managed Industrial Switch. Windows' Hyper Terminal program is a good choice.
Hyper Terminal can be accessed from the Start menu.
1. Click START, then Programs/Accessories and then Hyper Terminal.
When the following screen appears, make sure that the COM port should be
configured as:
Baud Rate: 9600 bps
Data Bits:
8
Parity: none
Stop Bit: 1
Flow control: None