9 panel switch commands, Esc c 5 n, Esc c 5 – Citizen Systems BD2-2220 User Manual
Page 97
- 97 -
2.2.9 Panel Switch Commands
ESC c 5 n
CT-S280
CT-S300
CT-S2000
CT-S4000
BD2-2220
CT-S310
support model
PMU2XXX
[Function]
Enabling/disabling the panel switches
[Code]
<
1B>H<63>H<35>H
[Range]
0≦n≦255
[Outline]
[The specification which is common to the model]
Enabling/disabling the FEED switch.
• “n” is valid only for the lowest bit (n0).
• Control by the lowest bit (n0) is shown as follows:
n0 Condition
0
FEED switch (LF-SW signal) valid
1
FEED switch (LF-SW signal) invalid
[Caution]
• When the FEED switch is disabled with this command, the paper cannot be fed by operating the
FEED switch.
• While switch operation is waited at the execution of macro, the FEED switch is always enabled
regardless of the setting of this command but no paper feed operation is carried out.
[Default] n=0
[Sample Program]
LPRINT CHR$(&H1B);"c5";CHR$(0); ・・・・・ When enabling the FEED switch
LPRINT CHR$(&H1B);"c5";CHR$(1); ・・・・・ When disabling the FEED switch