GS g 0 m nL nH

CT-S280 CT-S300 CT-S2000

CT-S4000

BD2-2220 CT-S310

support model

PMU2XXX

[Function]

Initializing maintenance counter

[Code]

<

1D>H<67>H<30>H

[Range] m=0

20≦(nL+nH×256)≦70(nL=20、21、50、70、nH=0)

[Outline]

[The specification which is common to the model]

Set the value of resettable maintenance counter specified to 0.
nL, nH are used to set the maintenance counter number to (nL+nH×256).

Counter Number

Counter Unit

Hex. Decimal

14 20

Paper-feed line[line]

15 21

Head powering count [times]

32 50

Auto-cutter drive count [times]

46 70

Product operation time[hours]

[Caution]

• This command, if used frequently, may destroy NV memory, thus write command to NV memory

shall be used less than [10 times/day] as a guideline.

• Along with processing this command, during data-writing to NV memory, printer BUSY may occur.

During the printer BUSY, to stop receive processing, this printer prohibits the data sending
(including real-time command) from host.