4.2.7 MSW7

MSW7-1: Baud rate

[Outline] Select baud rate which is serial interface communication condition.

Enabled if DSW1-1 OFF is set [following memory switch setting].

Setting Value

Baud Rate

1200bps,2400bps,4800bps,9600bps,19200bps,

38400bps,57600bps,115200bps


MSW7-2: Data length

[Outline] Select the data length, which is a serial interface communication condition.

Enabled if DSW1-1 OFF is set [following memory switch setting].

Setting Value

Data Length

7bits,8bits


MSW7-3: Stop bit

[Outline] Select the stop bit, which is a serial interface communication condition.

Enabled if DSW1-1 OFF is set [following memory switch setting].

Setting Value

Stop Bit

1bit,2bits


MSW7-4: Parity

[Outline] Select the parity, which is a serial interface communication condition.

Enabled if DSW1-1 OFF is set [following memory switch setting].

Setting Value

Parity NONE,

ODD,

EVEN


MSW7-5: Busy control

[Outline] Select the busy control, which is a serial interface communication condition.

Enabled if DSW1-1 OFF is set [following memory switch setting].

Setting Value

Flow Control

DTR/DSR, XON/XOFF