7 msw7 – Citizen Systems BD2-2220 User Manual
Page 289
- 289 -
4.2.7 MSW7
●MSW7-1: Baud rate
[Outline] Select baud rate which is serial interface communication condition.
Enabled if DSW1-1 OFF is set [following memory switch setting].
Setting Value
Baud Rate
1200bps,2400bps,4800bps,9600bps,19200bps,
38400bps,57600bps,115200bps
●MSW7-2: Data length
[Outline] Select the data length, which is a serial interface communication condition.
Enabled if DSW1-1 OFF is set [following memory switch setting].
Setting Value
Data Length
7bits,8bits
●MSW7-3: Stop bit
[Outline] Select the stop bit, which is a serial interface communication condition.
Enabled if DSW1-1 OFF is set [following memory switch setting].
Setting Value
Stop Bit
1bit,2bits
●MSW7-4: Parity
[Outline] Select the parity, which is a serial interface communication condition.
Enabled if DSW1-1 OFF is set [following memory switch setting].
Setting Value
Parity NONE,
ODD,
EVEN
●MSW7-5: Busy control
[Outline] Select the busy control, which is a serial interface communication condition.
Enabled if DSW1-1 OFF is set [following memory switch setting].
Setting Value
Flow Control
DTR/DSR, XON/XOFF