Gs g 2 m nl nh, Gs g 2 – Citizen Systems BD2-2220 User Manual
Page 127
- 127 -
GS g 2 m nL nH
CT-S280 CT-S300 CT-S2000
CT-S4000
BD2-2220 CT-S310
support model
PMU2XXX
[Function] Sending
maintenance
counter
[Code]
<
1D>H<67>H<32>H
[Range] m=0
20≦(nL+nH×256)≦198
nL=20、21、50、70、148、149、178、198
nH=0
[Outline]
[The specification which is common to the model]
Send the maintenance counter value specified.
nL, nH are used to set the maintenance counter number to (nL+nH×256).
Counter Number
Counter [Unit] Counter
Type
Hex. Decimal
14 20
Paper-feed line[line] Resettable
15 21
Head powering count [times] Resettable
32 50
Auto-cutter drive count [times] Resettable
46 70
Product operation time[hours] Resettable
94 148
Paper-feed line[line] Accumulated
95 149
Head powering count [times] Accumulated
B2 178
Auto-cutter drive count [times] Accumulated
C6 198
Product operation time[hours] Accumulated
• Configuration of data to be sent is shown below for the maintenance counter.
Hex. Decimal
Data
Count
Header
5FH 95 1 byte
30H~39H 48~57
Data
1 - 10 bytes
NUL
00H 0 1 byte
[Caution]
• During sending block data (maintenance counter value), real-time status and ASB status shall not
be sent. Thus, during sending the data, printer status can not be notified.
• Counter value sent by this command is only a guideline value. Due to an error occurrence and
power off timing, figure data may have an error.
• To update the flash memory, write the flash memory if any change occurs in the
maintenance counter when the period where the printer is not in operation (printing,
paper feeding, drawer, or cutting) lasts about 10 seconds, 2 minutes, and 1 hour.
• If change occurs in each counter, data on RAM is updated correspondingly.