Gs c 0 m n, Gs c 0 – Citizen Systems BD2-2220 User Manual
Page 145

- 145 -
GS C 0 m n
CT-S280
CT-S300
CT-S2000
CT-S4000
BD2-2220
CT-S310
support model
PMU2XXX
[Function]
Setting the numbering print mode
[Code]
<
1D>H<43>H<30>H
[Range]
0≦m≦5
0≦n≦2
[Outline]
[The specification which is common to the model]
This command sets the numbering (serial number counter) print mode.
“m” denotes the number of print columns.
m = 0
Prints the columns indicated by numeral. In this case, “n” has no meaning.
m = 1 to 5 Indicates the maximum number of columns to be printed.
Prints the counter in “m” columns.
“n” specifies a printing position within the printing columns.
n = 0
Prints the data right justified. The blank columns are spaced.
n = 1
Prints the data right justified. The blank columns are filled with "0".
n = 2
Prints the data left justified. The right blank will become invalid.
[Caution]
If either “m” or “n” has a value beyond their ranges, that setting will becomes invalid.
[Default] m=0、n=0
[See Also]
[Sample Program]
LPRINT CHR$(&H1D);"C0";
*CNT
LPRINT CHR$(0); CHR$(0);
FOR I=1 TO 5
GOUSAB
*CNT
LPRINT
CHR$(&H1D);"c";
LPRINT CHR$(&H1D);"C0";
NEXT I
LPRINT CHR$(1); CHR$(0);
LPRINT
CHR$(&HA);
GOUSAB
*CNT
RETURN
LPRINT CHR$(&H1D);"C0";
LPRINT CHR$(3);CHR$(0);
[Print Results]
GOUSAB *CNT
12345
67890
11 12 13 14 15
016017018019020
21 22 23 24 25
Counts from 1 to 5 at m = 0 and n = 0.
Counts from 6 to 10 at m = 1 and n = 0.
Counts from11 to 15 at m = 3 and n = 0.
Counts from 16 to 20 at m = 3 and n = 1.
Counts from 21 to 25 at m = 3 and n = 2.
LPRINT CHR$(&H1D);"C0";
LPRINT CHR$(3); CHR$(1);
GOUSAB *CNT
LPRINT CHR$(&H1D);"C0";
LPRINT CHR$(3); CHR$(2);
GOUSAB *CNT
END