beautypg.com

Function5, Gs ( c pl ph m fn b – Citizen Systems BD2-2220 User Manual

Page 116

background image

- 116 -

fn=553 Function 5 Sending Key Code List of Stored Record

GS ( C pL pH m fn b

[Code]

<

1D>H<28>H<43>H

[Range] (pL+pH×256)=3(pL=3、pH=0)

m=0
fn=5、53
b=0

[Outline]

[The specification which is common to the model]

Sends key code list of record existing in user NV memory.

Hex.

Decimal

Data size

Header 37H

55

1byte

Identifier 71H

113

1byte

Status 40Hor41H 64or65

1byte

2~80 bytes

Data 20H~FEH 32~254

NUL 00H

0

1byte

• Data is a data group with a list of key codes.

Transmission data group when record is not detected is as shown below.

Hex. Decimal

Data Size

Header 37H

55

1byte

Identifier 71H

113

1byte

Status 40H

64

1byte

NUL 00H

0

1byte

After sending [Header - NUL], receives a response from the host and executes the next processing
corresponding to the response.
• In case of “Status (with continuous block): hexadecimal number = 41H / decimal number = 65”

Response

Content of Processing

ASCII Decimal

ACK

6

Sends next data group.

NAK

21

Resends previous data group.

CAN 24

Cancels

processing.

• In case of “Status (last block): hexadecimal number = 40H / decimal number = 64”

Response

Content of Processing

ASCII Decimal

ACK 6

Terminates

processing.

NAK

21

Resends previous data group.

CAN 24

Cancels

processing.

This manual is related to the following products: