Gs c 2 n1 n2, Gs c 2 – Citizen Systems BD2-2220 User Manual
Page 147
- 147 -
GS C 2 n1 n2
CT-S280
CT-S300
CT-S2000
CT-S4000
BD2-2220
CT-S310
support model
PMU2XXX
[Function]
Setting the numbering counter
[Code]
<
1D>H<43>H<32>H
[Range]
0≦n1≦255
0≦n2≦255
[Outline]
[The specification which is common to the model]
This command sets the numbering (serial number counter) value.
n1+n2×256 (n1 = remainder, n2 = quotient) becomes a counter value.
[Caution]
• If the counter is set with this command, a repeat count of the identical count will be cleared.
• If the counter value is beyond the range specified with the GS C1 or GS C; command, the counter
will be initialized.
[Default]
Not defined.
[See Also]
[Sample Program]
[Print Results]
See the Sample Program and Print Results for the GS C1 command.