beautypg.com

5 msw5 – Citizen Systems BD2-2220 User Manual

Page 287

background image

- 287 -

4.2.5 MSW5

MSW5-1: Buzzer

[Outline] Select the enable/disable of buzzer.

OFF(0) ON(1)

Buzzer Valid Invalid

ON (1) OPERATION: Disable buzzer

When an error occurs or memory switch setting is changed manually, no buzzer sounds.

OFF (0) OPERATION: Enable buzzer.

When an error occurs or memory switch setting is changed manually, the buzzer sounds.


MSW5-2: Basic vertical calculation pitch

[Outline] Select the basic calculation pitch in the paper feed direction.

OFF(0) ON(1)

Line Pitch

360

406

ON (1) OPERATION: Basic vertical calculation pitch is set to 1/406 inch.

Line-feed length is 3.75mm by default.

OFF (0) OPERATION: Basic vertical calculation pitch is set to 1/360 inch.

Line-feed length is 4.23mm by default.


MSW5-3: USB mode

[Outline] Select

USB

mode.

OFF(0) ON(1)

USB Mode

Virtual COM

Printer Class

ON (1) OPERATION: Operated as Printer class
OFF (0) OPERATION: Operated as virtual COM class


MSW5-4: Reserved [Fixed to OFF (0)]

This manual is related to the following products: