Gs c 1 n1 n2 n3 n4 n5 n6, Gs c 1 – Citizen Systems BD2-2220 User Manual
Page 146
- 146 -
GS C 1 n1 n2 n3 n4 n5 n6
CT-S280
CT-S300
CT-S2000
CT-S4000
BD2-2220
CT-S310
support model
PMU2XXX
[Function]
Setting the numbering counter mode (A)
[Code]
<
1D>H<43>H<31>H
[Range]
0≦n1、n2、n3、n4、n5、n6≦255
[Outline]
[The specification which is common to the model]
This command sets the numbering (serial number counter) mode.
n1+n2×256 (n1 = remainder, n2 = quotient): Counter default
n3+n4×256 (n3 = remainder, n4 = quotient): Counter final value
n5: Counter step value
n6: Identical counter print counter
(n1+n2×256) < (n3+n4×256): Count-up system
(n1+n2×256) > (n3+n4×256): Count-down system
(n1+n2×256) = (n3+n4×256) or n5 = 0 or n6 = 0: Counter stop
[Default] n1+n2×256=1
n3+n4×256=65535
n5=1
n6=1
[See Also]
[Sample Program]
LPRINT CHR$(&H1D);"C0";
*CNT
LPRINT CHR$(3); CHR$(0);
FOR I=1 TO 5
LPRINT CHR$(&H1D);"C1";
LPRINT CHR$(&H1D);"c";
LPRINT CHR$(50); CHR$(0);
¥
NEXT I
LPRINT CHR$(0); CHR$(0);
¥
LPRINT CHR$(&HA);
LPRINT CHR$(5); CHR$(2);
RETURN
GOUSAB *CNT
LPRINT CHR$(&H1D);"C2";
LPRINT CHR$(5); CHR$(0); CHR$(10);
GOUSAB *CNT
END
[Print Results]
When printing the counter value by setting a count-down range = 0
to 50, step value = 5, repeat count = 2, and starting value = 50.
50 45 40
0
50 50 45 45 40
5
When printing the counter value by setting a count-down range to 0
to 50, step value = 5, repeat count = 1, and starting value = 5, step
cleared.