GS C 1 n1 n2 n3 n4 n5 n6

CT-S280

CT-S300

CT-S2000

CT-S4000

BD2-2220

CT-S310

support model

PMU2XXX

[Function]

Setting the numbering counter mode (A)

[Code]

<

1D>H<43>H<31>H

[Range]

0≦n1、n2、n3、n4、n5、n6≦255

[Outline]

[The specification which is common to the model]

This command sets the numbering (serial number counter) mode.

n1+n2×256 (n1 = remainder, n2 = quotient): Counter default
n3+n4×256 (n3 = remainder, n4 = quotient): Counter final value
n5: Counter step value
n6: Identical counter print counter
(n1+n2×256) < (n3+n4×256): Count-up system
(n1+n2×256) > (n3+n4×256): Count-down system
(n1+n2×256) = (n3+n4×256) or n5 = 0 or n6 = 0: Counter stop

[Default] n1+n2×256=1

n3+n4×256=65535
n5=1
n6=1

[See Also]

GS C 0

GS C 2

GS C;

GS c

[Sample Program]

LPRINT CHR$(&H1D);"C0";

*CNT

LPRINT CHR$(3); CHR$(0);

FOR I=1 TO 5

LPRINT CHR$(&H1D);"C1";

LPRINT CHR$(&H1D);"c";

LPRINT CHR$(50); CHR$(0);

¥

NEXT I

LPRINT CHR$(0); CHR$(0);

¥

LPRINT CHR$(&HA);

LPRINT CHR$(5); CHR$(2);

RETURN

GOUSAB *CNT
LPRINT CHR$(&H1D);"C2";
LPRINT CHR$(5); CHR$(0); CHR$(10);
GOUSAB *CNT
END

[Print Results]

When printing the counter value by setting a count-down range = 0
to 50, step value = 5, repeat count = 2, and starting value = 50.

50 45 40

0

50 50 45 45 40

5

When printing the counter value by setting a count-down range to 0
to 50, step value = 5, repeat count = 1, and starting value = 5, step
cleared.