• a=222: Head margin set by the value selected by (nL+nHx256).
• a = 202: Controls input buffer full Busy with the value selected by
(nL+nHx256) and controls Busy with output/cancel timing
(remaining capacity).
1≦(nL+nH×256)≦32767
Unit: 168dot
When Input Buffer
Capacity 4K Bytes
(Large) is Set
When Input Buffer
Capacity “Small” is Set
Initial value: 0dot
(nL+nHx256)
Output
Cancel
Output
Cancel
• a=223: Sets black mark bottom margin with the amount selected by
(nL+nHx256).
1 16
26
128
256
2 16
40
128
512
3 30
50
72
256
4 30
60
72
512
1≦(nL+nH×256)≦255
• XON/XOFF is also output by the establishment of conditions.
Unit: 1 dot
• Ignores the data received when input buffer idle capacity is 0.
Initial value: 34 dots
• a=220: Sets the maximum width of black mark by the amount selected by
(nL+nHx256).
• a=224: Sets cut distance with the value selected by (nL+nHx256).
1≦(nL+nH×256)≦255
1≦(nL+nH×256)≦32767
Unit: 1 dot
Unit: 1 dot
Initial value: 232 dots
Initial value: 40 dots
• a=225: Sets head distance with the value selected by (nL+nHx256).
• a=221: Sets the maximum length of black mark page with the value
selected by (nL+nHx256).
1≦(nL+nH×256)≦255
Unit: 1 dot
1≦(nL+nH×256)≦32767
Initial value: 56 dots
Unit: 1 dot
Initial value: 2360 dots