ESC p m n1 n2
CT-S280
CT-S300
CT-S2000
CT-S4000
BD2-2220
CT-S310
support model
PMU2XXX
[Function]
Generating the specified pulses
[Code]
<
1B>H<70>H
[Range]
m=0、1、48、49
0<n1≦n2≦255
[Outline]
[The specification which depend on the model]
• The signals specified by “n1” and “n2” are output to the connector pin specified by “m”.
• “m” has the followings.
m Connector
Pin
0, 48
Drawer kick-out pin No. 2
1, 49
Drawer kick-out pin No. 5
• The ON time is n1 x2 ms, and OFF time n2 x2 ms.
[Caution]
• When “m” is beyond a definition range, no signal is output, discarding “n1” and “n2”.
• The drawer drive duty must be within the following range:
ON time
ON time+OFF time
≦
0.2
(The OFF time should be 4 times or more longer than the ON time.)
[Sample Program]
LPRINT CHR$(&H1B) + "p"
LPRINT CHR$(0);
・・・・・
Selects pin No. 2.
LPRINT CHR$(5);
・・・・・
Sets ON time to 10 ms
LPRINT CHR$(50);
・・・・・
Sets OFF time to 100 ms