beautypg.com

Function64, Gs ( l pl ph m fn d1 d2 – Citizen Systems BD2-2220 User Manual

Page 121

background image

- 121 -

fn=64 Function 64 Sending Key Code List of Defined NV Graphics

GS ( L pL pH m fn d1 d2

[Code]

<

1D>H<28>H<4C>H

[Range] (pL+pH×256)=4(pL=4、pH=0)

m=48
fn=64
d1=75(“K”)
d2=67(“C”)

[Outline]

[The specification which is common to the model]

Sends the key code list of defined NV graphics.
• When key code list is present

Hex.

Decimal

Data Size

Header 37H

55

1

byte

Identifier 72H

114

1

byte

Status 40Hor41H

64or65

1

byte

Data

30H~39H

48~57

2~ 80 bytes

NUL 00H

0 1

byte

• When key code is not present


Hex.

Decimal

Data Size

Header 37H

55

1

byte

Identifier 72H

114

1

byte

Data 40H

64 1

byte

NUL 00H

0 1

byte

When 40 or more key codes are present, they are sent by being divided in unit of 40max.

• Status with continuous transmission data group is 41H.
• Status without continuous transmission data group is 40H.

After sending [Header - NUL], receives a response from the host and executes the next processing
corresponding to the response.
• In case of “Status (with continuous block): hexadecimal number = 41H / decimal number = 65”

Response

Content of Processing

ASCII Decimal

ACK 6

Sends next data group.

NAK

21

Resends previous data group.

CAN 24

Cancels

processing.

• In case of “Status (last block): hexadecimal number = 40H / decimal number = 64”

Response

Content of Processing

ASCII Decimal

ACK 6

Terminates processing.

NAK 21

Resends previous data group.

CAN 24

Cancels processing.