beautypg.com

Fn=3、51: function 3 sending use amount, Fn=4、52: function 4 sending remaining capacity, Function3 – Citizen Systems BD2-2220 User Manual

Page 115: Function4, Gs ( c pl ph m fn b

background image

- 115 -

fn=351 Function 3 Sending Use Amount

GS ( C pL pH m fn b

[Code]

<

1D>H<28>H<43>H

[Range] (pL+pH×256)=3(pL=3、pH=0)

m=0
fn=3、51
b=0

[Outline]

[The specification which is common to the model]

Sends the use amount of user NV memory (number of bytes of used area).

[Caution]

• This command uses 20 bytes for user NV management information beforehand and

sends the use amount of user NV memory by 20 bytes more than actual size.

Hex.

Decimal

Data Size

Header 37H 55 1byte

Identifier 28H

40 1byte

Capacity of use

30H~39H

48~57

1~6 bytes

NUL 00H 0 1byte


fn=452 Function 4 Sending Remaining Capacity

GS ( C pL pH m fn b

[Code]

<

1D>H<28>H<43>H

[Range] (pL+pH×256)=3(pL=3、pH=0)

m=0
fn=4、52
b=0

[Outline]

[The specification which is common to the model]

Sends the remaining capacity of user NV memory (number of bytes of unused area).

[Caution]

• This command uses 20 bytes for user NV management information beforehand and
sends the remaining capacity user NV memory by 20 bytes less than actual size.

Hex.

Decimal

Data Size

Header 37H 55 1byte

Identifier 29H

41 1byte

Capacity of use

30H~39H

48~57

1~6bytes

NUL 00H 0 1byte

This manual is related to the following products: