beautypg.com

Citizen Systems BD2-2220 User Manual

Page 190

background image

- 190 -

BD2-2220

• a = 5: When print density is specified

Setting Status

Sending Data

Stored

Value

Print Density

1st Byte 2nd Byte

3rd Byte

4th Byte

5th Byte

65530 70% 54(“6”)

53(“5”)

53(“5”)

51(“3”)

48(“0”)

65531 75% 54(“6”)

53(“5”)

53(“5”)

51(“3”)

49(“1”)

65532 80% 54(“6”)

53(“5”)

53(“5”)

51(“3”)

50(“2”)

65533 85% 54(“6”)

53(“5”)

53(“5”)

51(“3”)

51(“3”)

65534 90% 54(“6”)

53(“5”)

53(“5”)

51(“3”)

52(“4”)

65535 95% 54(“6”)

53(“5”)

53(“5”)

51(“3”)

53(“5”)

0 Basic

density

48(“0”) ―

1 105%

49(“1”)

2 110%

50(“2”)

3 115%

51(“3”)

4 120%

52(“4”)

5 125%

53(“5”)

6 130%

54(“6”)

7 135%

55(“7”)

8 140%

56(“8”)


• a = 6: When printing speed is specified

Setting Status

Sending Data

Stored

Value

Print Speed

1st Byte 2nd Byte

3rd Byte

4th Byte

5th Byte

1

Speed level 1

49(“1”)

2

Speed level 2

50(“2”)

3

Speed level 3

51(“3”)

4

Speed level 4

52(“4”)

5

Speed level 5

53(“5”)

6

Speed level 6

54(“6”)

7

Speed level 7

55(“7”)

8

Speed level 8

56(“8”)

9

Speed level 9

57(“9”)




• a = 201: When ACK output position is specified

Setting Status

Sending Data

Stored

Value

ACK Output

Position

1st Byte

2nd Byte

3rd Byte

4th Byte

5th Byte

1 ACK-in-Busy

49(“1”)

2 ACK-while-Busy

50(“2”)

3 ACK-after-Busy

51(“3”)


• a = 202: Input buffer full Busy output/cancel timing

Setting Status

Sending Data

Stored

Value

BUSY

Output/Cancel

1st Byte

2nd Byte

3rd Byte

4th Byte

5th Byte

1

49(“1”)

2

50(“2”)

3

51(“3”)

4 52(“4”)


This manual is related to the following products: