beautypg.com

5 examples of wiring, Symbols, Examples of wiring -7 – KEYENCE GL-RHG Series User Manual

Page 77: Symbols -7, Examples of wiring

background image

4-7

GL-RHG-M-NO4-E

Wirin

g

4

4-5

Examples of Wiring

Symbols

R1, R2

: External device (Safety PLC, Safety relay unit, etc)

K1, K2

: External device (Force guided relay, magnet contactor, etc)

K3

: Solid state contactor

*1

S1

: Switch used for reset input

S2

: Switch used for wait input

*1

S3

: Switch used for override input

L1

: Muting lamp (Incandescent lamp or LED lamp)

P1, P2

: Muting device (Self-contained photoelectric sensors, etc.)

M

: 3-phase motor

PLC

: For NON SAFETY-RELATED system control use

*1

*1

These are NON SAFETY-RELATED components

Reference

Grey wire (FE) is electrically-connected to the light curtain body case.

The light curtain body case and internal power signal lines are coupled by capacitor (3 kV, 100 pF).

NOTICE

If any input or output wires remain open (completely disconnected), they must be capped.