Monitor Tab
Allows the GL-RHG status to be monitored. Also, the non-safety outputs can be forcibly turned ON/OFF to
confirm operation.
"Non Safety-Related Outputs" (page 2-23)
Item
Description
Operation display
This displays the operation status of the GL-RHG main unit.
•
Operation status: Normal operation (Green)/Error (Red)/Wait input (white)/Muting
(orange)/Muting (No Bank) (orange)/Override (orange)
•
OSSD status: OSSD ON (Green)/OSSD OFF (Red)
•
Interlock status: Interlock Blocked (Yellow)/Interlock-reset-ready (Yellow)
* When OSSD is ON, the display is grayed out.
* The muting bank function and interlock function cannot be used with GL-RHG.
Function button/Main panel
Contents displayed on the main panel change depending on which function buttons are
selected.
(1)
Stop/Start
This starts or stops monitoring the amount of received light that the GL-RHG main unit
connected to the PC receives.
Peak-hold
When the checkbox is ON
, the line indicating the peak value for the amount of
received light is displayed in the [Amount of received light monitoring area].
Reverse order
When the checkbox is ON
, the main unit is displayed as the top unit in the image.
(2) Unit display
When serial connection is made, this shows which unit is set.
(3)
Amount of received light monitoring
area
Displays the amount of received light on the bar graph. As the bar extends to the right,
the amount of received light increases.
The color of the bar is green for light received and pink for light blocked.
Operation display
(1)
Function button
Main panel
(2)
(3)