beautypg.com

2 functions, Functions -4, Functions – KEYENCE GL-RHG Series User Manual

Page 28

background image

2-4

GL-RHG-M-NO2-E

Fu
nct
ion
s and

Feat

ures

2

2-2

Functions

The wiring system and the type of cable used with the GL-RHG determine the functions that can be used.

: Available without the configuration software

: Available with the configuration software

Wiring system

Optical

synchronization

One-line

Wire synchronization

Page

Cable

combination

Cable for the transmitter

5-core

Series

connection

7-core

11-core

Cable for the receiver

5-core 11-core 5-core 11-core 7-core 11-core 7-core 11-core

Available

function

OSSD output

2-5

AUX (auxiliary) output

2-23

Error output

2-24

Muting function

2-7

Muting lamp output

2-24

Override function

2-20

EDM function

2-6

Wait input

2-22

Reset input (for error)

A-4

Channel configuration
(Light interference prevention
function)

3-11

Center indicator configuration

5-4

Monitoring function

6-14

Requirement

Function

Page

Output a signal when an error occurs.

Error output function

2-24

Output a signal for monitoring by the PLC.

AUX output function

2-23

Suspend the GL-RHG's safety functions temporarily while the workpiece is passing
through the detection area.

Muting function

2-7

Suspend the GL-RHG's safety functions temporarily in order to activate the machine
while the workpiece remains in the detection area.

Override function

2-20

Separate the power supplies for the transmitter and receiver which are located far
away from each other.

Optical synchronization

2-2

Make sure whether the beam axes are optically aligned.

Monitoring function

6-14