Setting switch – KEYENCE GL-RHG Series User Manual
Page 23
1-2
Part Description
1-9
GL-RHG-M-NO1-E
Bef
o
re Use
1
Setting switch
Point
•
The configuration of the setting switch is applied when the power is supplied.
•
When the GL-RHG is in series connection, the setting switch configuration of the main unit
is applied regardless of the setting switch configuration of the sub unit.
•
When the GL-RHG operates in wire synchronization system, the setting switch for Channel
must be configured by default. Otherwise an error occurs.
DANGER
•
The response time varies according to the configuration of Channel.
"Response time (OSSD)" (page 7-5)
Transmitter
Receiver
Switch
No.
Function
Configuration
2
Channel
Channel 0
(Not applied)
(Default)
Use Channel for light
interference
prevention when
optical
synchronization
system is applied.
For details, refer to
Interference
Prevention Function"
(page 3-11)
Channel A
1
Channel B
2
1
2
1
2
1
Switch
No.
Function
Configuration
6
Center
indicator
ON (Green) when all beam axes are
clear (Default).
OFF when all beam axes are clear.
(Green OFF)
5
Not in use
Do not change from the default
position.
4
3
2
Channel
Channel 0
(Not applied)
(Default)
Use Channel for light
interference
prevention when
optical
synchronization
system is applied.
For details, refer to
Interference
Prevention Function"
(page 3-11)
Channel A
1
Channel B
6
6
5
4
3
2
1
2
1
2
1