I/o monitoring, I/o monitoring -15, Main panel – KEYENCE GL-RHG Series User Manual
Page 103: Output test
6-8
Monitor Tab
6-15
GL-RHG-M-NO6-E
Mo
ni
to
ring
me
th
o
d
U
sin
g t
h
e C
o
nf
ig
u
ra
tio
n
Sof
tw
are
6
I/O monitoring
Main panel
* Displayed items will differ depending on the GL-RHG configuration status.
Output test
When the output test button is clicked, the [Output test] dialog box appears. The displayed output function
varies depending on the GL-RHG configuration.
Item
Monitoring content
I/O monitoring Receiver*
This shows the ON/OFF status of each input/output. If the status is ON, the indicator lights
in green. If the status is OFF, the indicator turns off.
I/O monitoring Transmitter*
Muted condition monitoring
This shows whether the muting input and muting time satisfy the set muting conditions. If
the conditions are satisfied, the indicator lights in green. If not, the indicator lights in red.
Muting inputs sequence
This shows the sequence when the Muting input 1 and 2 were input last time.
Time between muting inputs
This shows the time difference when the Muting input 1 and 2 were input last time.
Maximum muting period
This shows the muting period when the muting status was established last time.
Muting bank applied
The muting bank function cannot be used with GL-RHG.
Output test
Setting contents
Item
Monitoring content
(1)
(2)
(3)
Item
Description
(1)
This displays the line color.
(2)
When the checkbox is ON
and the [Output] button is clicked, the output test is performed.
(3)
Select whether to forcibly turn the output ON or OFF when the output test is performed.
Output/Finish test
Each time the [Output] button is clicked, the output status is updated according to the configuration status.
When the [Finish test] button is clicked, the [Output test] dialog box is closed.