beautypg.com

KEYENCE GL-RHG Series User Manual

Page 39

background image

2-5

Temporary Suspension of Safety Function

2-15

GL-RHG-M-NO2-E

Fu
nct
ion
s and

Feat

ures

2

(3) The workpiece interrupts the beam

of sensor A1 first, and then inter-
rupts the beam of A2. Then, the
GL-RHG goes into the muted con-
dition and the OSSD does not turn
off even if the GL-RHG detects an
interruption.

Sensor A2

Safety zone

Hazardous zone

Receiver

Beam axis

Transmitter

GL-RHG

Workpiece

Movement

Sensor B2

Sensor B1

Sensor A1

V

Movement

V

(4) The workpiece is passing through

the detection area of the GL-RHG.
The GL-RHG still continues the
muted condition.

Sensor A2

Safety zone

Hazardous zone

Receiver

Beam axis

Transmitter

GL-RHG

Workpiece

Sensor B2

Sensor B1

Sensor A1

(5) The GL-RHG goes back to normal

operation (not muted) when sensor
B1 turns off after the workpiece has
been passed.

Movement

V

Sensor A2

Safety zone

Hazardous zone

Receiver

Beam
axis

Transmitter

GL-RHG

Workpiece

Sensor B2

Sensor B1

Sensor A1