Series connection

Up to three GL-RHG units can be serially connected and used as a single light curtain. The series con-
nection is available in all wiring system. The series connection cables that KEYENCE provides as an
optional part. (

"Series connection cable" (page 1-3))

Benefits

Prevents light interference between the connected GL-RHGs

Simplified wiring

Limitations

Up to 3 units

Up to 240 total number of beam axes (Up to 228 total number of beam axes when channel A or B is set
by selecting the optical synchronization system)

When one-line wiring system is applied, the total length of unit connection cable, extension cable and
series connection cables must be 30 m or less.

"1-2 Part Description" (page 1-8)
"4-4 Cable Specification" (page 4-6)

Point

Series connection is required for secure light interference prevention. When not connecting
the GL-RHG units in series, install the units by referring to

"Light Interference

Prevention Method" (page 3-11)

If the response time (ON OFF) exceeds 20 ms, this unit cannot be used as a certified
product based on the Chinese standard GB 4584 "
压力机用光电保护装置技术条件".

"Response time (OSSD)" (page 7-5)