beautypg.com

Explanation – KEYENCE GL-RHG Series User Manual

Page 35

background image

2-5

Temporary Suspension of Safety Function

2-11

GL-RHG-M-NO2-E

Fu
nct
ion
s and

Feat

ures

2

Explanation

(1) The workpiece is approaching the

protective zone but the GL-RHG
does not go into the muted condi-
tion because both muting input 1
and 2 are OFF. At this point, the
GL-RHG continues normal opera-
tion and OSSD goes OFF if the
GL-RHG gets interrupted.

Sensor A2

Safety zone

Hazardous zone

Receiver

Reflector

Reflector

Sensor A1

Beam axis

Transmitter

GL-RHG

Workpiece

Movement

(2) The workpiece interrupts the beam

from sensor A1 first, and then inter-
rupts the beam from sensor A2. The
GL-RHG then goes into the muted
condition and the OSSD does not
turn off even if the GL-RHG detects
an interruption.

Sensor A2

Safety zone

Hazardous zone

Receiver

Reflector

Reflector

Sensor A1

Beam axis

Transmitter

GL-RHG

Workpiece

Movement

(3) The GL-RHG goes back to nor-

mal operation (not muted) if either
sensor A1 or sensor A2 turns off
as the workpiece passes.

Sensor A2

Safety zone

Hazardous zone

Receiver

Reflector

Reflector

Sensor A1

Beam axis

Transmitter

GL-RHG

Workpiece

Movement