4 cable specification, Cable specification -6, Cable specification – KEYENCE GL-RHG Series User Manual
Page 76
4-6
GL-RHG-M-NO4-E
Wirin
g
4
4-4
Cable Specification
(1) Cable length
1. Optical synchronization system and wire synchronization system
The sum of the length for the unit connection cable and extension cable must be 30 m or less. This
limitation applies separately to the entire transmitter cable setup and the entire receiver cable
setup. There is no limitation for the total length of series connection cables when the GL-RHG is
connected in series.
2. One-line system
The sum of the length for all of the unit connection cables, extension cables and series connection
cables must be 30 m or less.
(2) Minimum cable bending radius : 5 mm
(3) Identification of connector cables
Connector colors
PNP output type cables or series connection cables
: Black connectors
NPN output type cables
: Grey connectors
Point
PNP output type cables and NPN output type cables cannot be used at the same time (mixed
wiring is not possible). One type of cable must be chosen based on the application.
(4) When using as safety device for press machine and shearing machine (paper cutting machine) in
Japan, make sure to attach cable protection pipes.
"Cable protection pipe" (page 1-4)
"3-6 Attaching the Cable Protection Pipe" (page 3-16)
DANGER
•
Cables must be within the lengths specified. Failure to follow this specification may cause
improper operation of safety functions, and may create a dangerous situation.
•
The series connection cable cannot be cut or extended. If the cable is cut or extended,
safety features may not operate properly. Do not allow this to happen as it is extremely
dangerous.
Connector