beautypg.com

1 troubleshooting, Error condition, Troubleshooting – KEYENCE GL-RHG Series User Manual

Page 126

background image

A-2

GL-RHG-M-NOA-E

App

end
ix

1

Troubleshooting

If the GL-RHG is not functioning normally, check the GL-RHG indicators first.

The GL-RHG is in an error condition under the following situations.

The center indicators blink in red.

The 7-segment display indicates "".

If the GL-RHG does not demonstrate the above situations, the GL-RHG is not in an error condition.

Error condition

The GL-RHG performs self-diagnosis for approx. 2 seconds after the power is turned on and checks for
errors. Self-diagnosis is also performed periodically during normal operations.
If the self-diagnosis function detects an error, the GL-RHG goes to an error condition and the OSSD is
kept in the OFF state even if no interruption exists in the protective zone. The indicators operate in the fol-
lowing manner during an error condition.

7-segment display

: Indication corresponding to the cause of the error

"Troubleshooting" (page A-2)

Center indicators

: All indicators are blinking in red.

"Center Indicator" (page 5-4)

Error output

: OFF

"Error output" (page 2-24)

To release the error condition, first remove the cause of the error, and then either activate the reset input
or turn the power off and on again.

Self-diagnosis description

Transmitter

Receiver

7-segment display

Function indicator

Transmitter

Error in the external power supply voltage

Failure in the internal power supply circuit

Failure in the light emitting element or light
receiving circuit

CPU overdrive

Memory error

Cable open/short-circuit

Receiver

Error in the external power supply voltage

Failure in the internal power supply circuit

Failure in the light receiving element or detec-
tion circuit

CPU overdrive

Memory error

Failure in the safety output circuit (OSSD)

Cable open/short-circuit

Program monitoring