Off information, Off information -16 – KEYENCE GL-RHG Series User Manual
Page 104
6-8
Monitor Tab
6-16
GL-RHG-M-NO6-E
Mo
ni
to
ring
me
th
o
d
U
sin
g t
h
e C
o
nf
ig
u
ra
tio
n
Sof
tw
are
6
OFF information
Point
If the power supplied to the GL-RHG main unit is turned off, the OFF information is erased.
Item
Description
(Detected position selection
button)
The beam axis No. which causes the OSSD OFF state is displayed with emphasis in the
"Amount of received light monitoring area".
(Number)
OSSD OFF occurrences are displayed. The history of the most recent OSSD OFF state is
numbered "1" and the oldest occurrence is numbered "20". Up to 20 OSSD OFF occurrences
are displayed.
(History details)
This displays factors that caused the OSSD OFF state. (Detection in detection zone, Error
occurred, etc.)
Time at OSSD OFF
This displays the date and time (time of occurrence) when OSSD OFF state occurred.
Detected position
This displays the detected beam axis number.
Detected period of time
This displays the duration of the detection.
Time at OSSD ON
This displays the date and time (for recovery) when the OSSD is switched from the OFF to ON
state.
When the OSSD state remains off, "OSSDs are in the OFF state." is displayed.
[Update] button
This refreshes to the latest OSSD OFF information.
Amount of received light
monitoring area