Light Interference Prevention Method

When more than one GL-RHG systems are installed, the OSSD may go to the OFF-state by the light inter-
ference between GL-RHG units.
There are three light interference prevention methods as follows.

Light Interference Prevention Function

When wire synchronization or one-line system is applied

The light interference prevention function automatically reduces mutual interference between GL-RHG
units.

When optical synchronization system is applied

The light interference prevention function is applied according to Channel configuration.
The mutual interference is reduced between GL-RHG units with Channel A and Channel B.
The mutual interference is not reduced between GL-RHG units with Channel 0 and Channel 0, GL-RHG
units with Channel 0 and Channel A, or GL-RHG units with Channel 0 and Channel B.

Channel is configured by using the setting switch on the lower part of front side of GL-RHG units.
Configure the same Channel to the setting switch on both the transmitter and receiver.
For more information about the setting switch, see

"Part Description" (page 1-8).

When the GL-RHG is in series connection, the setting switch configuration of the main unit is applied
regardless of the setting switch configuration of the sub unit.

"Wiring System" (page 2-2)

Series connection

Connecting the GL-RHG units in series can prevent mutual interference.

"Series connection" (page 2-3)

DANGER

The response time varies according to the configuration of Channel.

"Response time (OSSD)" (page 7-5)