5-2 Troubleshooting

5-4

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

5

Ap
pe

ndi
x

„

Network status indicator (NS)

This indicator indicates whether the DL-EP1 is communicating correctly with

EtherNet/IP.

„

Sensor communication indicator (D-bus)

This indicator indicates whether the DL-EP1 is communicating correctly with the

sensor amplifier.

If an error occurs, you can identify the cause of the error by reading the error code

via cyclic communication or message communication.

"Error code list" (Page 3-13)

LED Status

Condition

Corrective Action

Green

Solid

One or more connections are

normally established.

If multiple connections are used, the DL-EP1 may

be unable to communicate with EtherNet/IP even if

the green LED is solid.

Flashing

No connection is established.

Check if the DL-EP1 is registered in the scanner.

Red

Solid

A duplicated IP address was

detected.

Check if the IP address setting is duplicated with the

IP address setting of the scanner or other adaptors.

Flashing

One or more connections have

timed out.

Locate the connections that have timed out and

check the power status and wiring of the

communication device.

Not lit

Power is not supplied to the

DL-EP1.

• Check if the power supply is correctly

connected.

• Check if the DL-EP1 is correctly connected to the

sensor amplifier.

The IP address is not assigned.

Set the IP address.

LED

Status

Condition

Corrective Action

Solid green The DL-EP1 is communicating correctly with

the sensor amplifier.

-

Flashing

green

After power-on, the DL-EP1 is now starting

up.

After it has started up, the DL-EP1 automatically shifts

to the normal status.

Solid red

The DL-EP1 could not communicate with the

sensor amplifier during its start-up.

(Error ID number/code: 00H/52 or 00H/55)

• Check if the DL-EP1 is correctly connected to the

sensor amplifier and turn on the power again.

• Check if an unsupported sensor amplifier is

connected to the DL-EP1 and turn on the power

again.

• Check if the number of connected sensor

amplifiers exceeds the maximum number of

connectable units.

• Check if there is an electrical noise source around

the DL-EP1.

If the error cannot be recovered after checking the

above, contact your nearest Keyence office.

An attempt to assign an ID number has

failed.

(Error ID number/code: 00H/51)
The DL-EP1 could not communicate

continuously with the sensor amplifier for

one second or longer.

(Error ID number/code: 00H/57)
A system error may have occurred in the

DL-EP1.

Flashing

red

Repetition

of 4

consecutive

flashes)

A current limitation error occurred.

(Error ID number/code: 00H/56)

Check the sensor amplifier configuration.

An unsupported sensor amplifier was

connected.

(Error ID number/code: 00H/53)
Unconnectable models are mixed. (Error ID

number/code: 00H/54)

Flashing

red

(Flashing at

fixed

intervals)

Sometimes the DL-EP1 cannot temporarily

communicate with the sensor amplifier.

(Error ID number/code: 00H/57)

Check if there is an electrical noise source around

the DL-EP1. (The error is automatically reset if the

cause is removed.)

Not lit

Power is not supplied to the DL-EP1.

• Check if the DL-EP1 is correctly connected to the

sensor amplifier.

• Check if the power supply is correctly connected.