KEYENCE DL-EP1 User Manual
Page 82
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
3-4 Message Communication
3-52
3
Communi
cat
in
g wit
h the
IL Seri
es
030FH
(783)
Two-point tuning
HIGH side 1st point confirmation
operation request
Executes two-point tuning. For the operating
procedure, refer to the “IL Series User's Manual”.
0310H
(784)
Two-point tuning
HIGH side 2nd point confirmation
operation request
(Determine HIGH setting value.)
0311H
(785)
Two-point tuning
LOW side 1st point confirmation
operation request
0312H
(786)
Two-point tuning
LOW side 2nd point confirmation
operation request
(Determine LOW setting value.)
0313H
(787)
Calibration
SET1 Confirmation operation
request
Executes calibration.
Set the R.V. value to be displayed using "Calibration
function SET1" and "Calibration function SET2" of
the attributes for IL Series.
For the operating procedure, refer to the “IL Series
User's Manual”.
0314H
(788)
Calibration
SET2 Confirmation operation
request (Perform calibration.)
0315H
(789)
Calculated value two-point
calibration
SET1 Confirmation operation
request
Executes calculated value two-point calibration
(main unit only).
Set the R.V. value to be displayed using "Calculated
value two-point calibration function SET1" and
"Calculated value two-point calibration function
SET2" of the attributes for IL Series.
For the operating procedure, refer to the “IL Series
User's Manual”.
0316H
(790)
Calculated value two-point
calibration
SET2 Confirmation operation
request (Perform calculated value
two-point calibration.)
0317H
(791)
Calculated value three-point
calibration
SET1 Confirmation operation
request
Executes calculated value three-point calibration
(main unit only).
Set the R.V. value to be displayed using "Calculated
value three-point calibration function SET1" and
"Calculated value three-point calibration function
SET3" of the attributes for IL Series.
For the operating procedure, refer to the “IL Series
User's Manual”.
0318H
(792)
Calculated value three-point
calibration
SET2 Confirmation operation
request
0319H
(793)
Calculated three-point calibration
SET3 Confirmation operation
request (Perform calculated three-
point calibration.)
0320H
(794)
One-point tuning request for
diff. count filter
Executes one-point tuning for diff. count filter.
For the operating procedure, refer to the “IL Series
User's Manual”.
0321H
(795)
Two-point tuning
1st point confirmation operation
request for diff. count filter
Executes two-point tuning for diff. count filter.
For the operating procedure, refer to the “IL Series
User's Manual”.
0322H
(796)
Two-point tuning
2nd point confirmation operation
request for diff. count filter
(Determine HIGH and LOW
setting value.)
Attribute ID
Name
Description