beautypg.com

2 troubleshooting, Troubleshooting -3, Troubleshooting – KEYENCE DL-EP1 User Manual

Page 95

background image

5-3

5

Ap
pe

ndi
x

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

5-2

Troubleshooting

The indicator LEDs on the DL-EP1 can be used to determine the causes of errors.

„

Link/activity indicator (LINK/ACT)

This indicator indicates whether the DL-EP1 is communicating correctly.

„

Module status indicator (MS)

This indicator indicates whether the DL-EP1 is operating normally.

* The setting can be changed so that the red LED does not flash.

Link/activity indicator (Green)

Module status indicator (Green, Red)

Network status indicator (Green, Red)

Sensor communication indicator (Green, Red)

LED Status

Condition

Corrective Action

Green

Solid

The DL-EP1 is normally linked.

-

Flashing The DL-EP1 is normally linked and

is now exchanging data.

-

Not lit

Power is not supplied to the DL-

EP1.

The DL-EP1 is not linked.

• Check if the power supply is correctly

connected.

• Check if the DL-EP1 is correctly connected

to the sensor amplifier.

• Check if the IP address is correct.
• Check if the power supply of the

connected device or Ethernet switch is

correctly connected.

• Check if the cable is correctly connected.

LED Status

Condition

Corrective Action

Green Solid

The DL-EP1 is normally operating. -

Red

Solid

A system error may have occurred

in the DL-EP1.

Contact your nearest KEYENCE office.

Flashing

One or more of the connector

sensors are in the error or warning
status

*

.

One or more of the connector sensors are in
the error or warning status

*

.

The number of connected sensor

may have exceed the maximum

number of connectable units.

Check if the number of connected sensors is

less than or equal to the maximum number of

connectable units.

The IP address may be duplicated. Check if the IP address is duplicated.

Not lit

Power is not supplied to the DL-

EP1.

• Check if the power supply is correctly

connected.

• Check if the DL-EP1 is correctly connected

to the sensor amplifier.