beautypg.com

KEYENCE DL-EP1 User Manual

Page 21

background image

2-2 Installation and Connection to Sensor Amplifiers

2-5

2

Con

nect

io

n a
nd
Conf

ig

urat
io

n

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

3

Mount the supplied end units (OP-26751: a set of two pieces) on the outer

ends of the amplifier and the EtherNet/IP Compatible Network Unit DL-

EP1. Then, fix the end units with the screws on the top of each end unit (2

points x 2 units). (Tightening torque : 0.6 Nm or less)

Mount the end units in the same way as the EtherNet/IP Compatible Network
Unit DL-EP1.

z

Connecting to sensor amplifiers of panel mount type

1

Connect the sensor amplifier and the EtherNet/IP Compatible Network
Unit DL-EP1, with the optional expansion cable (OP-35361).

2

Remove the sensor amplifier connector (for DIN rail mount type) from the

EtherNet/IP Compatible Network Unit DL-EP1 using pliers. Then, attach

the expansion connector sticker supplied with the DL-EP1.

Press the EtherNet/IP Compatible Network Unit DL-EP1, into

full engagement with the sensor amplifier. Energizing the DL-

EP1 when not inserted fully may damage the DE-EP1.

• Turn off the power supply and connect the expansion

cable securely. Energizing the DL-EP1 when not inserted
fully may damage the DL-EP1.

• Attaching or detaching the cable when the power supply is

on may damage the DL-EP1.

End unit

End unit

NOTICE

Peel off the protective sticker.

Expansion cable (Cable length: 300 mm)

NOTICE

Sensor amplifier connector
(for DIN rail mounting type)

Expansion
connector sticker