3-4 Message Communication
3-35
3
Communi
cat
in
g wit
h the
IL Seri
es
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
00H
77H
(119)
Output4
(Alarm output)
Indicates the status of alarm output (output 4)
of each amplifier. When alarm is output, the bit
corresponding to the ID number of the sensor
amplifier is turned ON.
Bit 0 to bit 7: ID number 1 to ID number 8
Bit 8 to bit 15: Reserved for system
R
WORD
78H(120
)
Output5
(Unassigned)
(Unassigned)
−
−
79H
(121) to
89H
(137)
Reserved for system
8AH
(138)
Current Value 0
Invalid
When the current value 0 of each amplifier is
invalid, the bit of corresponding ID number is
turned ON.
Bit 0 to bit 7: ID number 1 to ID number 8
Bit 8 to bit 15: Reserved for system
R
WORD
8BH
(139)
Current Value 0
Under Range
When the current value 0 of each amplifier is
less than the lower limit of the detection range,
the bit of the corresponding ID number is
turned ON.
Bit 0 to bit 7: ID number 1 to ID number 8
Bit 8 to bit 15: Reserved for system
R
WORD
8CH
(140)
Current Value 0
Over Range
When the current value 0 of each amplifier is
higher than the upper limit of the detection
range, the bit of corresponding ID number is
turned ON.
Bit 0 to bit 7: ID number 1 to ID number 8
Bit 8 to bit 15: Reserved for system
R
WORD
8DH
(141)
Current Value 1
Invalid
(Unassigned)
R
WORD
8EH
(142)
Current Value 1
Under Range
(Unassigned)
R
WORD
8FH
(143)
Current Value 1
Over Range
(Unassigned)
R
WORD
90H
(144)
Current Value 0
(ID Number 1)
Indicates the current value 0 of the sensor of
ID number 1.
Parameter range:
-2147483648 to 2147483647
R
DINT
91H
(145) to
96H
(150)
:
97H
(151)
Current Value 0
(ID Number 8)
Indicates the current value 0 of the sensor ID
number 8.
Parameter range:
-2147483648 to 2147483647
R
DINT
98H
(152) to
AFH
(175)
Reserved for system
B0H
(176)
Sensor Status
Mask Setting
Set up the condition to determine if the sensor
error or warning is the recoverable DL-EP1
error (MS LED blinks in red). If mask is
selected, MS LED does not blink in red when
a sensor error or warning occurs.
Parameter range: 0 to 1 (initial value: 0)
0: Not mask
1: Mask
R/W
UINT
Instance
ID
Attribute
ID
Name
Description
Attribute
Data
Type