3-4 Message Communication

3-25

3

Communi

cat
in

g wit

h the

IL Seri

es

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

(5) Reading the number of decimal places from a sensor amplifier

Message communication reads the number of decimal places of settings read

from the sensor amplifier.

"(5) Reading the number of decimal places in the parameter from a sensor

amplifier" (Page 3-55)

For the IL Series, if the current value is 12.53 mm, data is stored as
follows:
Data: 12530
Number of decimal places: 3

Perform calculation from the read data and the number of decimal places.

Command

Response

DL-EP1

Scanner


Service code: 4CH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0325H(805)

IL

Reads the number of decimal
places of the IL Judgment value
(P.V. value).

Reference

1253012.53012.53mm

Number of
decimal places

3 2 1