KEYENCE DL-EP1 User Manual
Page 83
3-4 Message Communication
3-53
3
Communi
cat
in
g wit
h the
IL Seri
es
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
• Commands
• Responses (when successful)
• Responses (when unsuccessful)
For details on the attribute ID, settings, general status, and additional status of each
parameter, refer to
"DL Object (Class ID:67H)" (Page 3-32) and
Item
Description
Data Example
Service Code
Designates the "operation command (4BH)" (fixed
value).
4BH
Class ID
Designates DL Object (67H)(fixed value).
67H
Instance ID
Designates the ID number. The ID number (00H) of the
DL-EP1 cannot be designated.
08H
Attribute ID
Designates the attribute ID to be designated from
"Attribute".
"(3) Issuing operation commands to a
sensor amplifier" "Attribute IDs supported by the
instance service 4BH (operation command)" (Page 3-
0301H(769)
Service Data
There is no service response data.
-
Item
Description
Data Example
General status
A status (00H) is returned that indicates normal
completion of message communication.
00H
Service response data
There is no service response data.
-
Item
Description
Data Example
General status
A general status for the service is returned
08H
Additional status
An additional status is returned.
-
Service response data
There is no service response data.
-