- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

3-3 Cyclic communication

3-18

3

Communi

cat
in

g wit

h the

IL Seri

es

The following describes how the scanner cyclically communicates with the DL-EP1

(cyclic communication).

"Reading an output from a sensor amplifier" (Page 3-18)

"Entering an external input to a sensor amplifier" (Page 3-19)

"Reading judgment values (P.V. values) from sensor amplifiers" (Page 3-20)

For the message communication method, refer to

"Message communication"

(Page 3-4).

Reading an output from a sensor amplifier

Available outputs: HIGH, LOW, GO, and alarm output

Device assignments:

"Monitor Data (84 Words (168 Bytes)) Assembly Instance

(Instance ID): 64H" (Page 3-9)

This example shows how to read the HIGH output from the sensor amplifier ID01.

(1)The output from the sensor amplifier entered into the IN area via cyclic

communication.

Communication Methods

PLC

Output of sensor amplifier
IN area [18] Bit0

Sensor amplifier

(1)

Output

HIGH output of ID 01

1
0

ON

OFF