KEYENCE DL-EP1 User Manual
Page 126
5-5 Objects Usable by DL-EP1
5-34
Ethernet Link Object
5
Ap
pe
ndi
x
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
Reference 2) Control bits list
List of general and additional statuses returned to each service
Bit
Name
Description
0
Auto-negotiate
OFF: Auto-negotiation is disabled (communication
setting is fixed at 10 Mbps).
ON: Auto-negotiation is enabled (communication setting
is fixed at 100/10 Mbps auto).
1
ForcedDuplex Mode
OFF (fixed)
2 to 15
Reserved
OFF (fixed)
Error Code
General
Status
Additional
(Extended)
Status
Description
Get_Attributes_All
00H
-
The service has ended normally.
05H
-
The designated instance ID does not exist.
Get_Attribute_Single
00H
-
The service has ended normally.
05H
-
The designated instance ID does not exist.
14H
-
The designated attribute ID does not exist.
Set_Attribute_Single
00H
-
The service has ended normally.
05H
-
The designated instance ID does not exist.
09H
-
The written value is invalid.
0CH
-
The object cannot execute the requested
service in the current state.
0EH
-
The designated attribute ID cannot be written.
13H
-
The length of send data is too short.
14H
-
The designated attribute ID does not exist.
Others
08H
-
The designated service is not supported.