4 message communication, Communi cat in g wit h the il seri es – KEYENCE DL-EP1 User Manual
Page 74
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
3-4 Message Communication
3-44
3
Communi
cat
in
g wit
h the
IL Seri
es
Group4
038BH
(907)
Delay timer
Set up delay timer.
Parameter range: 0 to 3 (initial value: 0)
0:OFF
1:On delay
2:Off delay
3:One-shot
R/W
DINT
038CH
(908)
Timer duration
Set up timer duration (unit: ms).
Parameter range: 5 to 9999 (Initial value: 60)
R/W
DINT
038DH
(909)
Hysteresis
*2
Set up hysteresis.
Parameter range: 0.000 to 99.999
R/W
DINT
038EH
(910)
Analog output
scaling
*9
Set up analog output scaling. (Main unit only)
Parameter range: 0 to 1 (initial value: 0)
0:Initial state
1:Free range
2:Bank
R/W
DINT
038FH
(911)
Analog output -
upper limit
value
*2, *9
Set up upper limit of analog output.
Parameter range: -99.999 to 99.999
(Initial value: +10.000)
R/W
DINT
0390H
(912)
Analog output -
lower limit value
*2, *9
Set up lower limit of analog output.
Parameter range: -99.999 to 99.999
(initial value: -10.000)
R/W
DINT
0391H
(913)
External input
*10
Set up whether to change the function
assigned to external input 1/2/3/4 from the
initial state.
Parameter range: 0 to 1 (initial value: 0)
0:Initial state
1:User setting
R/W
DINT
0392H
(914)
External input 1
*10
Set up function to be assigned to external
input 1.
Parameter range: 0 to 4 (initial value: 0)
0:Zero shift input
1:Bank A input
2:Bank B input
3:Laser emission stop input
4:Not used
R/W
DINT
0393H
(915)
External input 2
*10
Set up function to be assigned to external
input 2.
Parameter range: 0 to 4 (initial value: 0)
0:Reset input
1:Bank A input
2:Bank B input
3:Laser emission stop input
4:Not used
R/W
DINT
0394H
(916)
External input 3
*10
Set up function to be assigned to external
input 3.
Parameter range: 0 to 4 (initial value: 0)
0:Timing input
1:Bank A input
2:Bank B input
3:Laser emission stop input
4:Not used
R/W
DINT
0395H
(917)
External input 4
*10
Set up function to be assigned to external
input 4.
Parameter range: 0 to 3 (initial value: 0)
0:Not used
1:Bank A input
2:Bank B input
3:Laser emission stop input
R/W
DINT
Class
Attribute
ID
Name
Description
Attribute
Data
Type