4 message communication, Communi cat in g wit h the il seri es – KEYENCE DL-EP1 User Manual
Page 72
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
3-4 Message Communication
3-42
3
Communi
cat
in
g wit
h the
IL Seri
es
Group3
0369H
(873)
System
parameter
settings
*6
Set up system parameter.
To reflect the setting, you need to send
"System parameter set request" (0306H (774))
operation command after writing the setting.
Use 0338H (824) to check the system
parameter with which the sensor amplifier is
operating.
bit 0:
0: NPN
1: PNP
bits 1, 2 and 3 (For main unit only. Fixed to
000 for expansion unit)
000: Analog output OFF
001: 0 to 5V
010: -5 to 5V
011: 1 to 5V
100: 4 to 20mA
R/W
DINT
036AH
(874)
Tolerance
tuning -
tolerance
setting range
Set up setting range for tolerance tuning.
Parameter range: 0.000 to 99.999
R/W
DINT
036BH
(875)
Calibration
function
Set up calibration function.
Parameter range: 0 to 1 (initial value: 0)
0:Initial state
1:User setting
R/W
DINT
036CH
(876)
Calibration
function SET1
*2
Set up target value of 1st point for calibration.
Parameter range: -99.999 to 99.999 (initial
value: 0.000)
R/W
DINT
036DH
(877)
Calibration
function SET2
*2
Set up target value of 2nd point for calibration.
Parameter range: -99.999 to 99.999
(initial value: +5.000)
R/W
DINT
036EH
(878)
Calculated
value
calibration
function
*9
Set up calculated value calibration function.
(Main unit only)
Parameter range: 0 to 2 (initial value: 0)
0:Initial state
1:Calculated 2-p calibration
2:Calculated 3-p calibration
R/W
DINT
036FH
(879)
Calculated
value two-point
calibration
function SET1
*2, *9
Set up target value of 1st point for calculated
value two-point calibration. (Main unit only)
Parameter range: -99.999 to 99.999
(initial value: +5.000)
R/W
DINT
0370H
(880)
Calculated
value two-point
calibration
function SET2
*2, *9
Calculated value two-point calibration function
SET2 (Main unit only)
Parameter range: -99.999 to 99.999
(initial value: +10.000)
R/W
DINT
0371H
(881)
Calculated
value three-
point calibration
function SET1
*2, *9
Set up target value of 1st point for calculated
value three-point calibration. (Main unit only)
Parameter range: -99.999 to 99.999
(initial value: +5.000)
R/W
DINT
0372H
(882)
Calculated
value three-
point calibration
function SET3
*2, *9
Set up target value of 3rd point for calculated
value three-point calibration. (Main unit only)
Parameter range: -99.999 to 99.999
(initial value: +10.000)
R/W
DINT
0373H
(883) to
037FH
(895)
(Reserved for system)
Class
Attribute
ID
Name
Description
Attribute
Data
Type