Objects usable by dl-ep1, Objects usable by dl-ep1 -28, 4 message communication – KEYENCE DL-EP1 User Manual
Page 58
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
3-4 Message Communication
3-28
3
Communi
cat
in
g wit
h the
IL Seri
es
The following describes the objects usable by the DL-EP1.
Objects Usable by DL-EP1
Command
Response
DL
Object
Message
Router
Object
Connection
Manager
Object
Assembly
Object
Identity
Object
TCP/IP
Interface
Object
Ethernet
Link
Object
EtherNet/IP unit
Object Name
Class ID
Description
Reference
Page
DL Object
67H
This object provides the statuses of the DL-EP1 and
the sensor amplifiers connected to the DL-EP1 and
writes and reads parameters. This object is unique to
the DL-EP1.
Identity Object
01H
This object provides identification information,
general information and a reset service, etc.
Message Router
Object
02H
This object provides connection points for message
communication.
Assembly Object
04H
This object provides access to the devices via cyclic
communication. This object can be used to send data
to the devices that do not support cyclic
communication.
Connection
Manager Object
06H
This object is used for connection-type
communication.
TCP/IP Interface
Object
F5H
This object provides the structure for setting the TCP/
IP network interface. You can set an IP address,
subnet mask and gateway, etc., in this object.
Ethernet Link Object
F6H
This object provides Ethernet status information.