beautypg.com

4 message communication, Communi cat in g wit h the il seri es – KEYENCE DL-EP1 User Manual

Page 75

background image

3-4 Message Communication

3-45

3

Communi

cat
in

g wit

h the

IL Seri

es

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

Group4

0396H

(918)

Bank switching

method

Set up method for switching the Bank.

Parameter range: 0 to 1 (initial value: 0)

0:Button

1:External input

R/W

DINT

0397H

(919)

(Reserved for system)

0398H

(920)

Zero shift value

memory

function

Set up whether to save the zero-shift state.

Parameter range: 0 to 1 (initial value: 0)

0: OFF

1: ON

R/W

DINT

0399H

(921)

Mutual

interference

prevention

function

*9

Set up mutual interference prevention

function.

Parameter range: 0 to 1 (initial value: 0)

0:Interference prevention OFF

1:Interference prevention ON

R/W

DINT

039AH

(922)

Display digit

Set up display digit. (initial value: 0)

0:Initial state

2:0.001

3:0.01

4:0.1

5:1

R/W

DINT

039BH

(923)

Power saving

function

Set up power saving mode.

Parameter range: 0 to 2 (initial value: 0)

0:OFF

1:Half

2:All

R/W

DINT

039CH

(924)

Head display

mode

Set up head display mode.

Parameter range: 0 to 2 (initial value: 0)

0:Initial state

1:OK/NG display

2:OFF

R/W

DINT

039DH

(925)

Display color

Set up display color of the amplifier.

Parameter range: 0 to 2 (initial value: 0)

0:GO Green

1:GO Red

2:Always Red

R/W

DINT

039EH

(926)

Timer duration

of diff. count

filter

Set up timer duration of diff. count filter (unit:

ms).

Parameter range: 2 to 9999 (initial value: 10)

R/W

DINT

039FH

(927)

Cutoff

frequency of

high-pass filter

Set up cutoff frequency of high-pass filter.

Parameter range: 0 to 9 (initial value: 10)

0: 0.1Hz

1: 0.2Hz

2: 0.5Hz

3: 1Hz

4: 2Hz

5: 5Hz

6: 10Hz

7: 20Hz

8: 50Hz

9: 100Hz

R/W

DINT

Group5

03A0H

(928)

Group5

Entry count

Indicates the No. of Group 5 entries.

Parameter range: 2

R

DINT

03A1H

(929)

Alarm setting

Set up alarm setting.

Parameter range: 0 to 2 (initial value: 0)

0:Initial state

1:Clamp

2:User setting

R

DINT

03A2H

(930)

Alarm count

Set up alarm count.

Parameter range: 2 to 1000 (initial value: 7)

R

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type