beautypg.com

KEYENCE DL-EP1 User Manual

Page 102

background image

5-4 Procedures for Communicating with an Allen-Bradley ControlLogix PLC

5-10

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

5

Ap
pe

ndi
x

2

Add the MSG instruction to the RsLogix5000 ladder.

3

Open the "Configuration" tab in the Message instruction setting dialog,
and change the MSG instruction setting.

Message Type
Select "CIP Generic".

ServiceType, Class, Instance, Attribute
Designate a value which matches the message to be sent.
• Example 1: Writing data to DL Object "Bank 0 HIGH setting" when writing

data to attributes

Item

Setting Value

ServiceType

SetAttributeSingle

ServiceCode

- (Cannot be designated)

Class

67H

Instance

01H

Attribute

0341H

SourceElement

Name of tag storing send data

SourceLength

4 byte (attribute size is 4)

Destination

- (Cannot be designated)