KEYENCE DL-EP1 User Manual
Page 54
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
3-4 Message Communication
3-24
3
Communi
cat
in
g wit
h the
IL Seri
es
(2) Writing data to a sensor amplifier
Message communication writes parameters to the DL-EP1 and the sensor
amplifier connected to the DL-EP1.
"(2) Writing parameters to a sensor amplifier" (Page 3-49)
(3) Issuing operation commands to a sensor amplifier
Message communication issues operation commands such as zero shift to the DL-
EP1 and the sensor amplifiers connected to the DL-EP1.
"(3) Issuing operation commands to a sensor amplifier" (Page 3-50)
(4) Locking sensor amplifier operations
Message communication locks operations by keys on the sensor amplifier
connected to the DL-EP1.
"(4) Locking sensor amplifier operations" (Page 3-54)
Command:
500
Response
Auto hold trigger level of the IL: 100500
DL-EP1
Scanner
Service code: 10H
Class ID: 67H
Instance ID: 01H
Attribute ID: 0389H (905)
Service data: 500
IL
Command
Response
The IL executes an operation assigned to
external input 1.
DL-EP1
Scanner
Service code: 4BH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0301H(769)
IL
Command
Response
Changes using the
sensor amplifier keys are locked.
DL-EP1
Scanner
Service code: 4CH
Class ID: 67H
Instance ID: 00H
Service data: 01H
IL