Using dl object, Using dl object -48, 1) reading parameters from a sensor amplifier – KEYENCE DL-EP1 User Manual
Page 78
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
3-4 Message Communication
3-48
3
Communi
cat
in
g wit
h the
IL Seri
es
The following describes how to perform message communication with a DL Object.
(1) Reading parameters from a sensor amplifier
(2) Writing parameters to a sensor amplifier
(3) Issuing operation commands to a sensor amplifier
(4) Locking sensor amplifier operations
(5) Reading the number of decimal places from a sensor amplifier
(1) Reading parameters from a sensor amplifier
Message communication reads each parameter from the DL-EP1 and the sensor
amplifier connected to the DL-EP1.
Service code 0EH is used.
The following settings are required to use this object.
• Service Code
• Class ID
• Instance ID
• Attribute ID
• Commands
• Responses (when successful)
Using DL Object
Item
Description
Data Example
Service Code
Designates "Parameter read (0EH)" (fixed value).
0EH
Class ID
Designates DL Object(67H) (fixed value).
67H
Instance ID
Designates the ID number.
0AH
Attribute ID
Designates the attribute ID to be read from "Attribute".
0324H(804)
Service Data
There is no service data.
-
Item
Description
Data Example
General status
A status (00H) is returned that indicates normal
completion of message communication.
00H
Service response data
The settings of the read parameter are returned.
0000H