4 message communication, Communi cat in g wit h the il seri es – KEYENCE DL-EP1 User Manual
Page 73
3-4 Message Communication
3-43
3
Communi
cat
in
g wit
h the
IL Seri
es
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
Group4
0380H
(896)
Group4 Entry
count
Indicates the No. of Group 4 entries.
Parameter range: 31
R
DINT
0381H
(897)
Calculation
function
*9
Set up calculation function.
Parameter range: 0 to 2 (initial value: 0)
0: OFF
1: Addition mode
2: Subtraction mode
R/W
DINT
0382H
(898)
(Reserved for system)
0383H
(899)
Measurement
direction
Set up measurement direction.
Parameter range: 0 to 1 (initial value: 0)
0:n or
1: rEv
R/W
DINT
0384H
(900)
Sampling cycle
Set up sampling cycle.
Parameter range: 0 to 4 (initial value: 0)
0:dEFLt
1: 0.33 ms
2: 1 ms
3: 2 ms
4: 5 ms
R/W
DINT
0385H
(901)
Averaging/Diff.
count filter/
High-pass filter
Set up averaging/diff. count filter/high-pass
filter.
Parameter range: 0 to 14 (initial value: 4)
0: 1 time
1: 2 times
2: 4 times
3: 8 times
4: 16 times
5: 32 times
6: 64 times
7: 128 times
8: 256 times
9: 512 times
10: 1024 times
11: 2048 times
12: 4096 times
13: Diff. count filter
14: High-pass filter
R/W
DINT
0386H
(902)
Output mode
Set up output mode.
Parameter range: 0 to 1 (initial value: 0)
0: N.O.
1: N.C.
R/W
DINT
0387H
(903)
(Reserved for system)
0388H
(904)
Hold function
setting
Set up hold function.
Parameter range: 0 to 5 (initial value: 0)
0:Sample hold
1:Peak hold
2:Bottom hold
3:Peak-to-peak hold
4:Auto peak hold
5:Auto bottom hold
R/W
DINT
0389H
(905)
Auto peak hold
or auto bottom
hold trigger
level
*2
Set up Auto-peak hold or Auto bottom hold
trigger level.
Parameter range: -99.999 to +99.999
(initial value: +1.000)
R/W
DINT
038AH
(906)
Timing input
setting
Set up timing input.
Parameter range: 0 to 1 (initial value: 0)
0:Level
1:Edge
R/W
DINT
Class
Attribute
ID
Name
Description
Attribute
Data