Group1

032AH

(810)

Analog output

value

Indicates the current analog output value.

(main unit only)

Parameter range:

Voltage: -5.000 to +5.000 (+5.500 for error)

4 to 20 mA: +4.00 to +20.00 (+3.00 for error)

OFF: Fixed to 0

R

DINT

032BH

(811)

Bank status

Indicates the currently active bank No.

Use this attribute to check the bank No. for

which the sensor amplifier is actually

operating.

Parameter range: 0 to 3

0: Bank 0

1: Bank 1

2: Bank 2

3: Bank 3

R

DINT

032CH

(812)

Timing status

Indicates the currently active timing status.

Use this attribute to check the timing status

under which the sensor amplifier is actually

operating.

Parameter range: 0 to 1

0: During Sampling

1: Not during sampling

R

DINT

032DH

(813) to

0331H

(817)

(Reserved for system)

0332H

(818)

Laser emission

stop status

Indicates the currently active laser emission

stop status.

Use this attribute to check the laser emission

stop status under which the sensor amplifier is

actually operating.

Parameter range: 0 to 1

0:Laser emitting

1:Laser stopped (Emission stop input ON/

Laser error/Sensor head error)

R

DINT

0333H

(819)

Abnormal

setting

*3

Indicates an abnormal setting status.

Parameter range: 0 to 1

0:Normal setting

1:Abnormal setting

R

DINT

0334H

(820)

External input

status

Indicates the external input status. When the

external input cable of the sensor amplifier or

the external input of the cyclic communication

is on, the corresponding bit turns on.

This operation is enabled even when "Not

used" is selected for the function setting of

external inputs 1 through 4.

Bit0:External input 1

Bit1:External input 2

Bit2:External input 3

Bit3:External input 4

R

DWORD

0335H

(821)

EEPROM write

result

*4

Indicates the result of writing to EEPROM.

Parameter range: 0 to 2

0:Writing

1:Normal termination

2:Abnormal termination

R

DINT

0336H

(822)

Zero shift/Zero

shift reset

result

*5

Indicates the result of zero shift or zero shift

reset.

Parameter range: 0 to 2

0:Executing

1:Normal termination

2:Abnormal termination

R

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type