beautypg.com

4 message communication, Communi cat in g wit h the il seri es – KEYENCE DL-EP1 User Manual

Page 67

background image

3-4 Message Communication

3-37

3

Communi

cat
in

g wit

h the

IL Seri

es

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

Attributes for IL Series

Designate the ID number (01H to 08H) of a sensor amplifier as the instance ID.

When the parameter range includes decimal data, a value should be read or

written as an integer by ignoring the decimal point. For example, when writing

"+1.235" as the HIGH-side setting value (BANK 0), write "+1235".

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Group1

0320H

(800)

Group1

Entry count

Indicates the number of items (entries) that

can be set in Group 1.

Parameter range: 29

R

DINT

0321H

(801)

Sensor amplifier

error

*1

Indicates the error status of the sensor

amplifier.

When an error occurs, the corresponding bit

turns on.

bit0: Overcurrent error

bit1: EEPROM error

bit2: Head error

bit7: Spot light laser error

bit8: Incompatible model error

bit11: Amplifier communication error

bit12: Number-of-units error

bit13: Calculation error

Other than above: Fixed to 0

R

DWORD

0322H

(802)

(Reserved for system)

0323H

(803)

(Reserved for system)

0324H

(804)

Judgment

output/Alarm

output

Indicates the output status of the sensor.

When an output is on, the corresponding bit

turns on.

Bit0:HIGH judgment output

Bit1:LOW judgment output

Bit2:GO judgment output

Bit3:Alarm output

R

DWORD

0325H

(805)

Judgment value

(P.V. Value)

*2,

Indicates the judgment value (P.V. value).

Parameter range: -99.999 to +99.999

R

DINT

0326H

(806)

Internal

measurement

value

(R.V. value)

*2

Indicates the internal measurement value

(R.V. value).

Parameter range:-99.999 to +99.999

R

DINT

0327H

(807)

Peak hold value

during hold

period

*2

In the mode other than the sample hold

mode

Indicates the peak-hold value during the

sampling period.

Parameter range:

-99.999 to +99.999

In the sample hold mode

Parameter range: -99.998

R

DINT

0328H

(808)

Bottom hold

value during

hold

period

*2

In the mode other than the sample hold

mode

Indicates the bottom-hold value during the

sampling period.

Parameter range:

-99.999 to +99.999

In the sample hold mode

Parameter range: -99.998

R

DINT

0329H

(809)

Calculation

value

(CALC value)

*2

Indicates calculation value (CALC value).

Parameter range: -99.999 to +99.999

R

DINT