KMC Controls FlexStat Operation Guide User Manual
Operation guide, Flexstat, Bacnet programmable thermostats contents

FlexStat
1
Operation Guide, Rev. R
Operation Guide
FlexStat
™
BACnet Programmable Thermostats
Contents
Overview ................................................................3
Applications and Installation ...................................3
Operation (Basic) ....................................................4
Navigation ..........................................................4
Room Temp. Setpoint Adjustment .......................4
H/C, Fan, Occupancy, and Override ...................4
Main Menu and Settings ......................................4
Display Options ..................................................5
Configuration (Setup) ..............................................6
Main Menu Overview .........................................6
About the FlexStat ...............................................6
Advanced Menu ..................................................7
(Advanced) Application and Additional Setup ..7
Auxiliary Heat (Heat Pump Only) Setup ......7
Damper Setup .............................................7
Fan Setup.....................................................8
Humidity Setup ...........................................8
Motion Sensor Setup ...................................8
Optimum Start Setup ..................................9
Sensor Setup ................................................9
Setback (OAT) Lockout Setup ....................10
Staging Setup .............................................10
Valve Setup ...............................................10
(Advanced) CB (Control Basic) Programs .......10
(Advanced) CO
Sensor (and DCV) ................11
Sensor Setup and Information ...........11
DCV (Demand Control Ventilation) Setup .11
(Advanced) Communications (BACnet) ..........14
(Advanced) Date/Time ...................................16
(Advanced) BACnet Device Properties ...........17
(Advanced) Inputs ..........................................17
(Advanced) Temp. Setpoint Limits ..................17
(Advanced) PID Loop Configuration ..............18
(Advanced) Restart/Restore ...........................18
(Advanced) Security Levels and Passwords .....18
(Advanced) Test ..............................................19
(Advanced) Trend Logs ...................................20
(Advanced) User Interface (UI) ......................21
Alarms ...............................................................23
Date/Time .........................................................23
DCV (Demand Control Ventilation) ..................24
Schedules ..........................................................24
Setpoints ...........................................................25
System Modes ...................................................25
Trend Viewer .....................................................26
Specifications, design, and operation are subject to change without notice.
Document Outline
- Cover/Contents
- Overview
- Applications and Installation
- Operation (Basic)
- Configuration (Setup)
- Main Menu Overview
- About the FlexStat
- Advanced Menu
- (Advanced) Application and Additional Setup
- (Advanced) CB (Control Basic) Programs
- (Advanced) CO2 Sensor (and DCV)
- (Advanced) Communications (BACnet)
- (Advanced) Date/Time
- (Advanced) BACnet Device Properties
- (Advanced) Inputs
- (Advanced) Temp. Setpoint Limits
- (Advanced) PID Loop Configuration
- (Advanced) Restart/Restore
- (Advanced) Security Levels and Passwords
- (Advanced) Test
- (Advanced) Trend Logs
- (Advanced) User Interface (UI)
- Alarms
- Date/Time
- DCV (Demand Control Ventilation)
- Schedules
- Setpoints
- System Modes
- Trend Viewer
- Resetting the FlexStat
- Network Connection
- Maintenance
- Programming (Custom)
- Accessories
- Firmware Upgrade
- Troubleshooting
- Alarm Issues
- Back-Up Issues
- Communication Issues
- Cover, Display, and Reset Issues
- Custom Programming and Web Issues
- Input, Sensor, and Value Issues
- CO2 Level Value Is Frozen or Is 0
- CO2 and DCV Sequences Are Not Working
- CO2 Level Is “Too High”
- DCV Menu Is Not Visible
- Input Values Are Outside the Expected Range
- Humidification/Dehumidification Issues
- Motion/Occupancy Sensor Does Not Work
- Temperature Reading Is Incorrect
- Temperature Setpoint Is Not Maintained
- Time and/or Date Are Not Correct
- Output, Fan, and Relay Issues
- Upgrading Firmware Issues
- Wiring Issues
- Support
- Important Notices
- Reference
- Index